Posted  by  admin

Red Lion Data Station Manual

Red Lion Data Station Manual 5,0/5 117 votes

. The CompactFlash card allows data to be collected and stored for later review. The files are stored in simple CSV file format allowing common The DSPZR was designed to act as a nexus for industrial data collection and applications, such as Microsoft Excel and Access, to view and manage the data. SAFETY SUMMARY 3.

  1. Red Lion Data Station Plus

LEDs: STS – Status LED indicates condition of Data Station. All safety related regulations, local codes and instructions that appear in the USB HOST – HOST LED indicates port status/activity.

Red Lion Data Station Plus manuals and user guides for free. Read online or download in PDF without registration.

Red Lion Data Station Plus

Manual or on equipment must be observed to ensure personal safety and to TX/RX –. In extremely high EMI environments, the use of external EMI suppression Visit RLC’s web site at for more information on EMI guidelines, Safety and CE issues as they relate to Red Lion Controls devices such as Ferrite Suppression Cores for signal and control cables is products. COMMUNICATION PORTS RS232/PG COMM CBLPROG0 COMM SLC 5/03 CPU POWER FORCE DH485 BATT RS232 PROG PWR OUT +24 USER POWER PWR OUT COM 120/240 VAC VAC NEUT CBLxxxxx.

CHASSIS GND RS232 SLC 5/03 CPU POWER FORCE DH485 BATT RS232 PROG COMM COMM PWR OUT +24. CABLES AND DRIVERS Note: The USB/PG port is for system set-up and diagnostics and is not intended Red Lion has a wide range of cables and drivers for use with many different for permanent connection. Communication types. A list of these drivers and cables along with pin outs is available from Red Lion’s website.

This information is stored in IBM (Windows ) PC compatible 130K FAT16 file format. Note: All Red Lion devices connect A to A and B to B. Refer to www.redlion.net for additional information. DH485 COMMUNICATIONS CompactFlash- Insert Top Side The DSPZR’s RS422/485 COMMS port can also be used for Allen Bradley. Antenna (G3QANT00) is NOT included with the card. Must be purchased separately if needed.

Manual

Industrial grade two million write cycles. SMART Modular Technologies model SG9CF (UL Listed Directory Category NWGQ). Red Lion offers RJ modular jack adapters. Refer to the DR literature for complete details.

The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing.

Red Lion Controls Plus Red Lion's Data Station Plus is the single-device solution for protocol conversion. The DSP bridges the communication gap between disparate serial, Ethernet and fieldbus devices - unlocking untold information from PLCs, drives, motion controllers, etc., orphaned by incompatible communications standards. Drag and drop register mapping allows a Siemens PLC to talk to an Allen Bradley drive in just seconds. With a growing list of over 300 serial, Ethernet and fieldbus drivers, the DSP allows you to choose the best-in-class automation components, without worrying over whether or not they'll communicate with one another.

DSP Series The Data Station Plus was designed to act as a nexus for industrial data collection and management. The unit offers multiple protocol conversion, data logging and remote machine access. With three built in serial ports and a 10 Base-T/100 Base-TX Ethernet port, the unit performs protocol conversion, allowing disparate devices to communicate seamlessly with one another. The Ethernet port supports up to ten protocols simultaneously using Crimson 3, so even Ethernet to Ethernet protocols can be converted. The CompactFlash card allows data to be collected and stored for later review. The files are stored in simple CSV file format allowing common applications, such as Microsoft Excel and Access, to view and manage the data.

The free Websync utility provides a means to synchronize the files with a PC's hard drive for permanent storage. The CompactFlash card may also be used to load new configuration files into the Data Station. If you are looking for Red Lion Data Station Plus, please call us on (844) 331-9379 or email us at we will do our best to help you find the DSPGT000 protocol converter that you are looking for at competitive prices. If you are searching for DSPGT001 data logger technical information (data-sheets) please use the datasheets or product selection guide page links. DSPZR Series The DSPZR leverages over 250 communications drivers via three independent serial ports and an Ethernet port, to connect and collect data from virtually any PLC, drive, bar code scanner, etc. The DSPZR's built-in data-logger will log tags at user-programmable rates, and automatically time/date stamp them.

The information is stored in open CSV file format, allowing you to access them with virtually any application. The DSPZR can synchronize the log files with any FTP server and/or Microsoft's SQL Server for further analysis.

The DSPZR extends production monitoring to remote personnel by providing email and text alerts, and its built-in webserver allows information to be monitored via any networked PC or smart-phone. If enabled, remote personnel can take partial or full control of the system remotely, allowing a maintenance person to effect changes without a site visit. DSPLE Series Data points logged from devices, machines and processes provide a performance baseline for analysis, and can be used to trigger PLC functions, alarms or notifications when points stray from nominal parameters. These variables can be used as reliable predictors of impending machine failure, monitoring for preventative maintenance, as well as general performance monitoring of distributed processes or discrete production throughput. Reliable data can be used to identify process vulnerabilities, abnormal conditions or wear trending.

Data Logging can be used for real-time monitoring of process activities, product traceability and quality control issues, TPM, downtime, OEE (overall equipment effectiveness), or be used to generate virtually unlimited data sets for statistical analysis and control decisions. One Data Station Plus allows a user to quickly set up monitoring of a number of disparate devices in a control application, collect performance data, display it, store it for evaluation, or trigger PLC functions, either live or remotely. The Data Station Plus' built-in math capability also allows probability calculations to pre-analyze hard point data to provide only relevant information. An integrated OPC server allows easy SCADA connectivity using Red Lion's OPCWorx.

Our industrial factory automation supplies distributors warehouse in Boise, Idaho USA stocks some DSPLE000 protocol converters enabling us to further assist you in finding the correct DSPLE001 protocol converter for your application in the USA, Canada and Mexico. Whether we have DSPSX000 data loggers in stock in Boise, Idaho USA or need to get them from Red Lion Controls; Clearwater Tech can get Red Lion DSPSX001 data logger to you fast and save you some money! It will be very helpful if you have the Red Lion DSPZR000 high performance protocol converter part numbers ready, then our sales representatives can provide you with a pricing and availability quote for protocol conversion devices that you are looking for in seconds. If you do not have the part numbers for Red Lion data station plus, our application engineers will be able to help you figure out the part numbers and get the price quote to you as soon as possible. Part No: OR Manufacturer: Can't find a part number? NK Transducers is factory applied on the mating surfaces to prevent rust and improve performance. AT Series transducers combine a current transformer and a signal conditioner into a single package.

This provides higher accuracy, lower wiring costs, easier installation and save valuable panel space. AT Series are available in solid or split core with 4-20ma, 0-5VDC or 0-10 VDC outputs. Select AT Series for constant Leuze Relays safety relay is used as a contact extension module in accordance with DIN EN 60204-1/VDE 0113 Part 1 for contact extension for E-Stop relays and two-hand control units. Depending on the wiring and proper integration of the feedback path, a Performance Level PL e in accordance with EN ISO 13849-1 is achieved. The MSI-SR4 is used for evaluating safety-sensor input signals. Light curtains, E-Stop buttons and safety switches.